Related Experiment Video
Updated: May 28, 2026

Composition and Distribution Analysis of Bioaerosols Under Different Environmental Conditions
Published on: January 7, 2019
Workplace aerosol mass concentration measurement using optical particle counters.
Peter Görner1, Xavier Simon, Denis Bémer
1Institut National de Recherche et de Sécurité, 1 rue du Morvan, CS 60027, 54519 Vandoeuvre-lès-Nancy, France.
Direct-reading aerosol measurement using optical particle counters (OPC) can accurately assess workplace particle mass concentration. This method correlates well with traditional sampling, offering a more comprehensive analysis of inhalable and respirable fractions.
Area of Science:
- Occupational Hygiene
- Aerosol Science
- Environmental Monitoring
Background:
- Direct-reading aerosol measurement relies on optical properties, with photometry and optical particle counting (OPC) being common methods.
- Mass concentration measurement is crucial for occupational hygiene, but photometry can be biased by particle size distribution.
- OPC measures particle number and size, enabling mass concentration assessment for spherical particles of known density.
Purpose of the Study:
- To evaluate the field calibration of an optical particle counter (OPC) for measuring workplace aerosol mass concentration.
- To compare OPC-derived mass concentration data with conventional gravimetric sampling methods.
- To assess the OPC's ability to measure inhalable, respirable, and thoracic aerosol fractions.
Main Methods:
- An adapted OPC (GRIMM® 1.108) was used to measure aerosol concentrations in a food industry setting with a mixed calcium carbonate and fungi spore aerosol.
- Simultaneous sampling was performed using CIP 10-Inhalable and CIP 10-Respirable (ARELCO®) samplers.
- OPC data, including particle size distribution and estimated particle density, were used to calculate mass concentration.
Main Results:
- Calculated inhalable and respirable aerosol fractions from OPC data showed close correlation with results from size-selective sampling.
- The modified OPC inlet demonstrated adequate sampling of inhalable aerosol across the workplace particle-size distribution.
- OPC data enabled the calculation of the thoracic aerosol fraction, valuable for assessing allergenic particles.
Conclusions:
- Field calibration of OPCs is feasible for accurate workplace aerosol mass concentration monitoring.
- OPCs offer a more comprehensive assessment of aerosol exposure, including fractions not directly measured by traditional samplers.
- The adapted OPC provides reliable data for occupational hygiene assessments, particularly for mixed aerosols and allergenic particles.
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.

