Pacemaker and implantable cardioverter-defibrillator use in a US myotonic dystrophy type 1 population
Deepak Bhakta1, Changyu Shen, Jack Kron
1Division of Cardiology, Department of Medicine, Krannert Institute of Cardiology Department of Biostatistics, Indiana University, Indianapolis, Indiana, USA.
Introduction:
We assessed implant rates, indications, characteristics, and outcomes in patients with the neuromuscular disease, myotonic dystrophy type 1 (DM1) receiving a pacemaker or an implantable cardioverter-defibrillator (ICD).
Methods And Results:
Device use was evaluated in a prospective, multicenter registry of 406 genetically confirmed adult patients followed for 9.5 ± 3.2 years. Forty-six (11.3%) had or received a pacemaker and 21 (5.2%) received an ICD. Devices were primarily implanted for asymptomatic conduction abnormalities and left ventricular (LV) systolic dysfunction. However, 7 (15.2%) pacemakers were implanted for third-degree atrioventricular block and 6 (28.6%) ICDs were implanted for ventricular tachyarrhythmias (ventricular tachycardia [VT] or fibrillation [VF]). Patients receiving devices were older and more frequently had heart failure, LV systolic dysfunction, atrial tachyarrhythmias, and ECG conduction abnormalities compared to nondevice patients. Five (10.9%) pacemaker patients underwent upgrade to an ICD, 3 for LV systolic dysfunction, 1 for VT/VF, and 1 for progressive conduction disease. Seventeen (27.4%) of the 62 patients with devices were pacemaker-dependent at last follow-up. Three (14.3%) ICD patients had appropriate therapies. Twenty-four (52.2%) pacemaker patients died including 13 of respiratory failure and 7 of sudden death. Seven (33.3%) ICD patients died including 2 of respiratory failure and 3 of sudden death. The patients with ICDs and sudden death all had LV systolic dysfunction and 1 death was documented due to inappropriate therapies.
Conclusions:
DM1 patients commonly receive antiarrhythmia devices. The risk of VT/VF and sudden death suggests that ICDs rather than pacemakers should be considered for these patients.