Disinfection of bacterially contaminated hydrophilic PVS impression materials
Emad Wadie Estafanous1, Charles John Palenik, Jeffrey A Platt
1Department of Prosthodontics, University of Iowa College of Dentistry, Iowa City, IA 52242, USA. emad-estafanous@uiowa.edu
Purpose:
This study evaluated disinfection of bacterially contaminated hydrophilic polyvinylsiloxane (PVS) and polyether impressions.
Materials And Methods:
Four light-bodied PVS (Examix, Genie, Take 1, Aquasil) and one polyether (Impregum) impression materials were evaluated using three disinfectants (EcoTru [EnviroSystems], ProSpray [Certol], and bleach [diluted 1:9]) as spray and immersion disinfections for 10-minute exposures. Pseudomonas aeruginosa ATCC 15442, Salmonella choleraesius ATCC 10708, and Staphylococcus aureus ATCC 6538 was the microbial challenge. Test specimens were prepared using aluminum molds with ten tapered cones. Mucin covered each cone, followed by 0.01 mL of each bacterium. Impressions were made using low viscosity impression material that was injected over the cones and filled custom trays. One-half of the impressions were spray disinfected, while the others underwent immersion disinfection. Trays that were contaminated but not disinfected served as positive controls, while those not bacterially contaminated or disinfected served as negative controls. The impressions were poured with Silky Rock Die Stone, and after setting, two cones were placed within a sterile capsule and triturated into powder. Four milliliters of TRIS buffer (0.05 M, pH 7.0) containing sodium thiosulfate (0.0055% w/v) were poured in each tube. After mixing, the solution was serially diluted and spread-plated onto selective agars. After incubation, colony counting occurred.
Results:
No viable bacteria transferred to casts from either spray- or immersion-disinfected impressions. Negative controls produced no microbial colonies. Positive controls produced on average 3.35 × 10(5) bacterial cells.
Conclusion:
Results suggest the methods used could disinfect contaminated impression materials. Microbial transfer from nondisinfected impressions to cones approached 33.5%.
Related Concept Videos
Hand hygiene
Hand washing...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Chemical Agents for Microbial Control