Effects of temperature and time delay on arterial blood gas and electrolyte measurements

Panida Srisan1, Teerasak Udomsri, Pravit Jetanachai

  • 1Department of Pediatrics, Queen Sirikit National Institute of Child Health, College of Medicine, Rangsit University, Bangkok, Thailand. psrisan@yahoo.com

Abstract

Related Concept Videos

Temperature Measurement Sites01:14

Temperature Measurement Sites

A thermometer measures body temperature. The common sites for measuring body temperature are the oral cavity, axillary region, temporal artery, and skin surface, such as the forehead, abdomen, and axilla. True core body temperature is assessed in the rectum, tympanic membrane, pulmonary artery, esophagus, and urinary bladder.
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Blood Studies I: ABG and VBG01:26

Blood Studies I: ABG and VBG

Blood studies are critical in the medical field, enabling healthcare professionals to assess a patient's health status accurately. This page will focus on two significant blood studies: Arterial Blood Gas (ABG) and Venous Blood Gas (VBG).
Arterial Blood Gas (ABG)
Arterial Blood Gas (ABG) studies are crucial for assessing the lungs' ability to supply oxygen and remove carbon dioxide, reflecting the patient's ventilation status. They also help understand the kidneys' capacity to reabsorb or...
Assessing Body Temperature - Temporal Artery01:19

Assessing Body Temperature - Temporal Artery

Here is a stepwise guide to assessing the body temperature at the temporal artery using a temporal artery thermometer
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.  
Step 3: Assess the patient's forehead...
Equipments Used to Measure Body Temperature01:13

Equipments Used to Measure Body Temperature

Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Errors occurring during blood pressure monitoring01:25

Errors occurring during blood pressure monitoring

Blood pressure monitoring is a crucial clinical procedure in diagnosing and managing various cardiovascular conditions. Despite its significance, the accuracy of blood pressure measurements can be compromised by multiple factors, potentially leading to either falsely high or low readings. These inaccuracies are critical as they can significantly impact patient care. So, it is vital to understand these challenges deeply and adopt strategic approaches to minimize errors.
Several factors...
Disorders of Acid-Base Balance01:29

Disorders of Acid-Base Balance

The human body maintains a precise pH range of arterial blood between 7.35 and 7.45. Deviations result in either acidosis (pH < 7.35) or alkalosis (pH > 7.45). These conditions are further classified as respiratory or metabolic disorders based on their underlying cause.
Respiratory Acidosis and Alkalosis
Respiratory acidosis occurs due to an increase in the partial pressure of carbon dioxide PCO2 in the blood. It often arises from shallow breathing or impaired gas exchange caused by...