Related Experiment Video
Updated: May 27, 2026

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Effects of anatomy and particle size on nasal sprays and nebulizers
Dennis O Frank1, Julia S Kimbell, Sachin Pawar
1Department of Otolaryngology/Head and Neck Surgery, University of North Carolina, Chapel Hill, North Carolina, USA.
Objective:
To study the effects of nasal deformity on aerosol penetration past the nasal valve (NV) for varying particle sizes using sprays or nebulizers.
Study Design:
Computed mathematical nasal airway model.
Setting:
Department computer lab.
Subjects And Methods:
Particle deposition was analyzed using a computational fluid dynamics model of the human nose with leftward septal deviation and compensatory right inferior turbinate hypertrophy. Sprays were simulated for 10 µm, 20 µm, 50 µm, or particle sizes following a Rosin Rammler particle size distribution (10-110 µm), at speeds of 1, 3, or 10 meters per second. Nebulization was simulated for 1, 3.2, 6.42, or 10 µm particles. Steady state inspiratory airflow was simulated at 15.7 liters per minute.
Results:
Sprays predicted higher NV penetration on the right side for particle sizes >10 µm, with comparable penetration on both sides at 10 µm. Nearly 100% deposited in the nasal passages for all spray characteristics. Nebulizer predictions showed nearly 100% of particles <6.42 µm and more than 50% of 6.42 µm bypassing both sides of the nose without depositing. Of the nebulized particles that deposited, penetration was higher on the right at 10 µm, with comparable penetration on both sides at 6.42 µm. Spray penetration was highest at 10 µm, with more than 96% penetrating on both sides at 1 and 3 meters per second. Nebulization penetration was also highest at 10 µm (40% on the left, >90% on the right).
Conclusion:
In the presence of a septal deviation, sprays or nebulizers containing 10-µm particles may have good penetration beyond the NV. Nebulized particles <10 µm are likely to be respirable. Additionally, spray speeds above 3 meters per second may limit penetration.
Related Concept Videos
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Inhaled Medications
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by anesthetizing...
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Drug Delivery: Miscellaneous Routes
Oral inhalation and nasal sprays swiftly transfer drugs across the respiratory epithelium's mucosal layer. Inhaled glucocorticoids and bronchodilators directly target lung conditions such as asthma, while fluticasone nasal spray mitigates allergic rhinitis.
Transdermal patches transport drugs through the...