Related Experiment Video
Updated: May 27, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Prospects of jugular venous pulse assessment
1General Medicine Unit with Diabetes and Endocrinology Service, Bir Hospital, National Academy of Medical Sciences, Kathmandu, Nepal. mdb@ntc.net.np
Abstract:
There is no controversy regarding the current clinical method of examination of waveform of jugular vein pulse. However there are limitations of clinical assessment of central venous pressure by jugular vein pressure measurement from the level of sternal angle. There are variations in the reported distances from sternal angle to right atrium as well as to upper limit of JVP. In erect position, anterior end of fourth intercostal space is at about the level of mid-right atrium. In patients with visible JVP at neck in erect position, measurement of CVP can be done more accurately directly from the anterior end of fourth intercostal space. For others, the position of mid-right atrium can be marked in lateral chest wall first in erect position at the mid-point of an anteroposterior line from anterior end of fourth intercostal space to back. Subsequently in reclining position, the vertical height of venous pressure can be measured from the horizontal plane of the midpoint marked at lateral chest wall to visible upper limit of JVP. Such measurement can be done in a more reliable way with venous pressure (VP) manometer with its indicator rod at the horizontal plane of mid-right atrium and with its horizontal surface at upper limit of JVP. The venous pressure manometer can also be used to measure relatively less reliable upper limb venous pressure (ULVP), as indicated by the vertical distance at which veins of upper limb collapse, especially when JVP is not visualized due to subnormal CVP as in hypovolemia.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Pulse Assessment Sites
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

