A dual-tuned quadrature volume coil with mixed λ/2 and λ/4 microstrip resonators for multinuclear MRSI at 7 T
Yong Pang1, Zhentian Xie, Duan Xu
1Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA 94158-2330, USA.
Abstract:
In this work, an eight-element by eight-element dual-tuned quadrature volume coil with a mix of capacitor terminated half-wavelength (λ/2) and quarter-wavelength (λ/4) microstrip resonators is proposed for multinuclear magnetic resonance imaging/spectroscopy studies at 7 T. In the proton channel, λ/2 microstrip resonators with capacitive terminations on both ends are employed for operation at higher frequency of 298.1 MHz; in the heteronucleus channel, capacitor-terminated λ/4 resonators, suitable for low frequency operations, are used to meet the low frequency requirement. This mixed structure design is particularly advantageous for high field heteronuclei magnetic resonance applications with large difference in Larmor frequency of the nuclei in question. The proposed design method makes it much easier to perform frequency tuning for heteronucleus channel using a variable capacitor with a practical capacitance range. As an example, a dual-tuned volume coil for (1)H/(13)C mouse spectroscopic imaging was proposed to demonstrate the feasibility of this method. The finite-difference time-domain method is first used to model this dual-tuned volume coil and calculate the B(1) field distributions at two frequencies. Transmission parameters (S(21)) measured between the proton channel and the carbon channel are -50 dB at 75 MHz and -35 dB at 298 MHz, showing the excellent isolation between the two channels at 7 T. The proton image and (13)C FIDCSI image of a corn oil phantom on the axial plane at 7 T demonstrate the feasibility of the proposed method. A preliminary proton image of a mouse on the sagittal plane is also acquired using the proposed dual-tuned volume coil at 7 T, illustrating a fairly uniform B(1) field and sufficient image coverage for imaging in mice.
Related Concept Videos
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Atomic Nuclei: Magnetic Resonance
Mass Analyzers: Common Types
¹H NMR: Complex Splitting
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied first.
NMR Spectrometers: Resolution and Error Correction
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule