Related Experiment Video
Updated: May 27, 2026

Tracking Microbial Contamination in Retail Environments Using Fluorescent Powder - A Retail Delicatessen Environment Example
Published on: March 5, 2014
Application of electrolyzed oxidizing water to reduce Listeria monocytogenes on ready-to-eat meats
1Department of Food Science, 111 Borland Laboratory, The Pennsylvania State University, University Park, PA 16802, USA.
Abstract:
Experiments were conducted to determine the effectiveness of acidic (EOA) or basic electrolyzed oxidizing (EOB) water, alone or in combination, on ready-to-eat (RTE) meats to reduce Listeria monocytogenes (LM). Frankfurters or ham surfaces were experimentally inoculated with LM and subjected to dipping or spraying treatments (25 or 4°C for up to 30 min) with EOA, EOB, and other food grade compounds. LM was reduced the greatest when frankfurters were treated with EOA and dipped at 25°C for 15 min. A combination spray application of EOB/EOA also resulted in a slight reduction of LM on frankfurters and ham. However, reductions greater than 1log CFU/g were not observed for the duration of the study. Even with a prolonged contact time, treatments with EOA or EOB were not enough to meet regulatory requirements for control of LM on RTE meats. As such, additional studies to identify food grade antimicrobials to control the pathogen on RTE meats are warranted.
More Related Videos
07:07Controlled-release of Chlorine Dioxide in a Perforated Packaging System to Extend the Storage Life and Improve the Safety of Grape Tomatoes
Published on: April 7, 2017
14:17The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Temperature
Methods of Controlling Food Spoilage
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Pasteurization and Food Preservation
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...