Related Experiment Video
Updated: May 27, 2026

Home-Based Monitor for Gait and Activity Analysis
Published on: August 8, 2019
Development of custom measurement system for biomechanical evaluation of independent wheelchair transfers
Alicia M Koontz1, Yen-Sheng Lin, Padmaja Kankipati
1Human Engineering Research Laboratories (151R1-H), VA Pittsburgh Healthcare System, 7180 Highland Dr, 151R1-H, Pittsburgh, PA 15206, USA. akoontz@pitt.edu
Abstract:
This study describes a new custom measurement system designed to investigate the biomechanics of sitting-pivot wheelchair transfers and assesses the reliability of selected biomechanical variables. Variables assessed include horizontal and vertical reaction forces underneath both hands and three-dimensional trunk, shoulder, and elbow range of motion. We examined the reliability of these measures between 5 consecutive transfer trials for 5 subjects with spinal cord injury and 12 nondisabled subjects while they performed a self-selected sitting pivot transfer from a wheelchair to a level bench. A majority of the biomechanical variables demonstrated moderate to excellent reliability (r > 0.6). The transfer measurement system recorded reliable and valid biomechanical data for future studies of sitting-pivot wheelchair transfers.We recommend a minimum of five transfer trials to obtain a reliable measure of transfer technique for future studies.