Resonant Mie scattering (RMieS) correction applied to FTIR images of biological tissue samples

Keith R Bambery1, Bayden R Wood, Don McNaughton

  • 1Centre for Biospectroscopy and School of Chemistry, Monash University, Clayton, Victoria, 3800, Australia.

The Analyst
|November 15, 2011
PubMed

Related Concept Videos

NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
IR Frequency Region: Fingerprint Region01:03

IR Frequency Region: Fingerprint Region

IR spectra are divided into two main regions: the diagnostic region and the fingerprint region. The diagnostic region of the spectrum lies above 1500 cm−1. The absorptions resulting from single-bond vibrations of the N–H, C–H, and O–H stretch at higher wavenumbers and appear on the left side of the spectrum. The stretching absorptions of the C≡C and C≡N occur between 2100–2300 cm−1. In contrast, those arising from stretching absorptions of the C=O, C=N, and C=C occur between 1600–1850 cm−1.
The...
Raman Spectroscopy: Overview01:20

Raman Spectroscopy: Overview

The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...