Mercury policy and regulations for coal-fired power plants

Manuela Rallo1, M Antonia Lopez-Anton, M Luisa Contreras

  • 1Energy and Sustainability Research Division, Faculty of Engineering, University Park, University of Nottingham, Nottingham, NG7 2RD, UK.

Abstract

Related Concept Videos

Nuclear Power02:36

Nuclear Power

Controlled nuclear fission reactions are used to generate electricity. Any nuclear reactor that produces power via the fission of uranium or plutonium by bombardment with neutrons has six components: nuclear fuel consisting of fissionable material, a nuclear moderator, a neutron source, control rods, reactor coolant, and a shield and containment system.
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
Nuclear Fission02:50

Nuclear Fission

Many heavier elements with smaller binding energies per nucleon can decompose into more stable elements that have intermediate mass numbers and larger binding energies per nucleon—that is, mass numbers and binding energies per nucleon that are closer to the “peak” of the binding energy graph near 56. Sometimes neutrons are also produced. This decomposition of a large nucleus into smaller pieces is called fission. The breaking is rather random with the formation of a large number of different...
Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
Turbine-Governor Control01:17

Turbine-Governor Control

Turbine-governor control is crucial for maintaining power system stability by balancing turbine mechanical power output with electrical load demand. This mechanism ensures that generator frequency and rotor speed are within acceptable limits during load variations. Turbine-generator units store kinetic energy due to their rotating masses; this energy is released to meet the load requirement when the load increases. The electrical torque of turbines rises to meet the demand, whereas the...
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
Generator Voltage Control01:21

Generator Voltage Control

Generator voltage control is crucial for maintaining the stable operation of synchronous generators and wind turbines. In older models, a DC generator driven by the rotor delivers DC power to the rotor's field winding, and the power is transferred through slip rings and brushes. In the latest models, static or brushless exciters are used. Static exciters rectify AC power from the generator terminals and then transfer the DC power directly to the rotor. Brushless exciters, on the other hand, use...