Related Experiment Video
Updated: May 27, 2026

A Novel Bioreactor for High Density Cultivation of Diverse Microbial Communities
Published on: December 25, 2015
Performance of sequencing batch biofilm reactors with different control systems in treating synthetic municipal
Yunxiao Jin1, Dahu Ding, Chuanping Feng
1School of Water Resources and Environment, China University of Geosciences, No. 29 Xueyuan Road, Beijing 100083, China.
Abstract:
This study aimed to evaluate the performances of sequencing batch biofilm reactors (SBBRs) in removing nitrogen and phosphorus from synthetic municipal wastewater with different carbon to total nitrogen (C/N) ratios. The effect of control systems, including an intelligent control system (ICS) and conventional timer control system (TCS) on the performance of SBBRs was also investigated. When C/N ratios were 10.0, 5.0 and 3.3, the average COD removal efficiencies in the ICS-SBBR reached 87.7%, 92.3% and 97.6%, while total phosphorous (TP) removals reached 95.0%, 97.0% and 97.2%. When the C/N ratio was 5.0, the TN removal efficiency was 81.0% under ICS and 65.4% under TCS. Moreover, compared with TCS-SBBR, both reaction time and aeration time were shortened by 180 min and 157 min, respectively, in the ICS-SBBR. Therefore, the ICS-SBBR has potential in practical applications for significant nitrogen and phosphorus removal and energy savings.
Related Concept Videos
Bioreactor Design and Operational System
Bioreactor Controls-I
Bioreactor Controls-II
Bioreactor Controls-III
Batch vs Continuous Culture
Environmental Applications of Microorganisms