Published on: February 6, 2019
A Monte Carlo model of the Varian IGRT couch top for RapidArc QA
1Department of Physics and Astronomy, University of British-Columbia, Vancouver, Canada. tteke2@bccancer.bc.ca
Abstract:
The objectives of this study are to evaluate the effect of couch attenuation on quality assurance (QA) results and to present a couch top model for Monte Carlo (MC) dose calculation for RapidArc treatments. The IGRT couch top is modelled in Eclipse as a thin skin of higher density material with a homogeneous fill of foam of lower density and attenuation. The IGRT couch structure consists of two longitudinal sections referred to as thick and thin. The Hounsfield Unit (HU) characterization of the couch structure was determined using a cylindrical phantom by comparing ion chamber measurements with the dose predicted by the treatment planning system (TPS). The optimal set of HU for the inside of the couch and the surface shell was found to be respectively -960 and -700 HU in agreement with Vanetti et al (2009 Phys. Med. Biol. 54 N157-66). For each plan, the final dose calculation was performed with the thin, thick and without the couch top. Dose differences up to 2.6% were observed with TPS calculated doses not including the couch and up to 3.4% with MC not including the couch and were found to be treatment specific. A MC couch top model was created based on the TPS geometrical model. The carbon fibre couch top skin was modelled using carbon graphite; the density was adjusted until good agreement with experimental data was observed, while the density of the foam inside was kept constant. The accuracy of the couch top model was evaluated by comparison with ion chamber measurements and TPS calculated dose combined with a 3D gamma analysis. Similar to the TPS case, a single graphite density can be used for both the thin and thick MC couch top models. Results showed good agreement with ion chamber measurements (within 1.2%) and with TPS (within 1%). For each plan, over 95% of the points passed the 3D gamma test.
More Related Videos
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...