Quantifying X-Ray Fluorescence Data Using MAPS
Published on: February 17, 2018
[The influence of the gain on ignition and correction in X-ray fluorescence spectrometry]
Qian Wang1, Xiao-Hu Ying, Jian-Bo Zhang
1Ningbo Entry-Exit Inspection and Quarantine Administration, Ningbo 315012, China. wangqian.nb@gmail.com
Abstract:
Research on the gain on ignition question for preparing ore with fusion sample preparation technique was done, and a new correction method was worked out. After fusion sample preparation, sulphide ore would have a lot of sulfate, which would change the sample matrix dramatically, and the matrix effect was corrected with errors. In this paper, a new solution to measuring gain on ignition was put forward, and it was committed step that the sample having gain on ignition was redefined by sample having loss on ignition. Through conversion, the gain on ignition was corrected by subtraction method, and the matrix effect was corrected by theoretical influence coefficients. The analysis results of redefinition samples were converted into the primal samples lastly. The project took copper concentrates as the experimental object, it was found that the gain on ignition of this method was obviously different from the gravimetric method, but through influence evaluation, this error had little effect on test results, and may be reduced by flux. After correction of the gain on ignition, the standard deviation of the elements calibration curves for Cu, Fe and S were less than 0.14%, 0.074% and 0.14% respectively, which were obviousely superior to 0.21%, 0.15% and 0.19%. The results got from this method were in satisfactory agreement with certified values.
Related Concept Videos
Atomic Emission Spectroscopy: Interference
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Spectroscopy: Absorption, Emission, and Fluorescence
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences