Related Experiment Video
Updated: May 27, 2026

Leveraging Turbidity and Thromboelastography for Complementary Clot Characterization
Published on: June 4, 2020
Thromboelastography in healthy, sick non-septic and septic neonatal foals
J L Mendez-Angulo1, M Mudge, S Zaldivar-Lopez
1Veterinary Population Medicine, University of Minnesota, Saint Paul, 55108, USA. v12meanj@uco.es
Objectives:
To evaluate citrated recalcified thromboelastography (TEG) in healthy newborn foals, and to determine intra-assay, inter-individual and intra-individual (at 12 h, 24 h and 7 days after birth) variations. Additionally, to compare TEG variables, haematological values and conventional coagulation profiles from healthy, sick non-septic, and septic foals.
Design:
Prospective study.
Methods:
The study group comprised 18 healthy, 15 sick non-septic and 17 septic foals. Two citrated (3.2%; 1 : 9 anticoagulant : blood ratio) blood samples were submitted for haemostatic evaluation using a TEG analyser and conventional coagulation profile. TEG values (R time (R), K time (K), angle (α), maximum amplitude (MA) and G value (G)), complete blood count (CBC) and conventional coagulation profile (prothrombin time (PT), activated partial thromboplastin time (aPTT), fibrinogen concentration (Fib) and antithrombin (AT)) were evaluated. Signalment, presenting complaint, sepsis scores, blood culture results and outcome were taken from the medical records of the sick foals.
Results:
Mean values ± SD for TEG variables in healthy neonatal foals were: R = 11.82 ± 5.35 min, K = 3.06 ± 1.34 min, α= 51.19 ± 12.66 degrees, MA = 55.06 ± 6.67 mm and G = 6361 ± 1700 dyn/cm(2) . Mean coefficients of variation for intra-assay/inter-individual/intra-individual in healthy foals were: R = 3.5/45.2/43.1%; K = 5.3/58.7/28.7%; α= 1.5/24.7/11.9%; MA = 0.3/12.1/6.1%; G = 1.6/26.7/14.7%. Septic foals had significantly greater α, MA and G values than sick non-septic foals, and significantly greater MA and G than healthy foals, changes that are consistent with hypercoagulability. Weak correlations were detected between TEG variables and haematological or haemostatic values.
Conclusions:
TEG could be used to provide additional information about the haemostatic system in equine neonates.
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...