Related Experiment Video
Updated: May 27, 2026

High-resolution Thermal Micro-imaging Using Europium Chelate Luminescent Coatings
Published on: April 16, 2017
Thermal performance in high power SHG characterized by phase-matched calorimetry
Hwan Hong Lim1, Toshio Katagai, Sunao Kurimura
1National Institute for Materials Science (NIMS), 1-1 Namiki, Tsukuba-shi, Ibaraki 305-0044, Japan.
Abstract:
We proposed a method to determine device quality in heat removal. Temperature change depending on SH power was analyzed by fitting with a new model to characterize heat removal performance of SHG modules, named as phase-matched calorimetry (PMC). The thermal disposal performance of SHG devices was improved by combination of metal housing and reduced crystal aperture. With a tight aperture, we demonstrated a 19 W single-pass 532-nm SHG at a conversion efficiency of 26.5% in a 10-mm-long PPMgSLT crystal without saturation.
Related Concept Videos
Calorimetry
Specific Heat
For example, increasing the temperature of one gram of water by 1°C requires one calorie of heat energy and can be written as 1 cal/g-°C, or 4186 J/kg/K.
Constant Pressure Calorimetry
Constant Volume Calorimetry
Mechanisms of Heat Transfer II
Quantifying Heat