Related Experiment Video
Updated: May 27, 2026

3D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Image reconstruction in phase-contrast tomography exploiting the second-order statistical properties of the
Cheng-Ying Chou1, Pin-Yu Huang
1Department of Bio-Industrial Mechatronics Engineering, National Taiwan University, 1, Sec. 4, Roosevelt Rd., Taipei, Taiwan 106 Taiwan. chengying@ntu.edu.tw
Abstract:
X-ray phase-contrast tomography (PCT) methods seek to quantitatively reconstruct separate images that depict an object's absorption and refractive contrasts. Most PCT reconstruction algorithms generally operate by explicitly or implicitly performing the decoupling of the projected absorption and phase properties at each tomographic view angle by use of a phase-retrieval formula. However, the presence of zero-frequency singularity in the Fourier-based phase retrieval formulas will lead to a strong noise amplification in the projection estimate and the subsequent refractive image obtained using conventional algorithms like filtered backprojection (FBP). Tomographic reconstruction by use of statistical methods can account for the noise model and a priori information, and thereby can produce images with better quality over conventional filtered backprojection algorithms. In this work, we demonstrate an iterative image reconstruction method that exploits the second-order statistical properties of the projection data can mitigate noise amplification in PCT. The autocovariance function of the reconstructed refractive images was empirically computed and shows smaller and shorter noise correlation compared to those obtained using the FBP and unweighted penalized least-squares methods. Concepts from statistical decision theory are applied to demonstrate that the statistical properties of images produced by our method can improve signal detectability.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

