[Preparation and evaluation of open tubular capillary electrochromatographic column modified with carboxymethyl
Sunying Zhou1, Xucong Lin, Zenghong Xie
1Institute of Food Safety and Environmental Monitoring, Fuzhou University, Fuzhou 350108, China.
Abstract:
Via covalent coupling of epoxy group, an open tubular column covalently modified with carboxymethyl chitosan (CMC) as stationary phase was prepared. The parameters of column pretreatment, silanization and chemically bonding of CMC were optimized. The morphology of inner wall of the open tubular column was observed by scanning electron microscope (SEM), which showed that the inner wall of the prepared column was evenly coated with a polymer film. Either positive or negative electroosmotic flow (EOF) could be achieved by varying the pH values of running buffer. Good reproducibility was obtained with the relative standard deviations (RSDs) of EOF less than 0.8% for run-to-run (n = 6), less than 3.5% for day-to-day (n = 3), less than 4.3% for column-to-column (n = 3) and less than 6.1% for batch-to-batch (n = 3). Nucleotides (AMP, GMP, CMP and UMP) were analyzed on the open tubular column modified with CMC, with high column efficiencies ranging from 36 000 to 182 000 plates/m. The results indicate that the developed method is effective, easy and stable.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
11:44Cellular Membrane Affinity Chromatography Columns to Identify Specialized Plant Metabolites Interacting with Immobilized Tropomyosin Kinase Receptor B
Published on: January 19, 2022
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Principles Of Column Chromatography
Ion-Exchange Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...