Related Experiment Video
Updated: May 27, 2026

Double-barreled and Concentric Microelectrodes for Measurement of Extracellular Ion Signals in Brain Tissue
Published on: September 5, 2015
Ion-selective electrodes with unusual response functions: simultaneous formation of ionophore-primary ion complexes
Masafumi Miyake1, Li D Chen, Gianluca Pozzi
1Department of Chemistry, University of Minnesota, 207 Pleasant Street SE, Minneapolis, Minnesota 55455, United States.
Abstract:
It is well known that the selectivity of an ion-selective electrode (ISE) depends on the stoichiometry of the complexes between its ionophore and the target and interfering ions. It is all the more surprising that the possibility for the simultaneous occurrence of multiple target ion complexes with different complex stoichiometries was mostly ignored in the past. Here, we report on the simultaneous formation of 1:1 and 1:2 complexes of a fluorophilic crown ether in fluorous ISE membranes and how this results in what looks like super-Nernstian responses. These increased response slopes are not caused by mass transfer limitations and can be readily explained with a phase boundary model, a finding that is supported by experimentally determined complex formation constants and excellent fits of response curves. Not only Cs(+) but also the smaller ions Li(+), Na(+), K(+), and NH(4)(+) form 1:1 and 1:2 complexes with the fluorophilic crown ether, with cumulative formation constants of up to 10(15.0) and 10(21.0) for of the 1:1 and 1:2 complexes, respectively. Super-Nernstian responses of the type observed with these electrodes are probably not particularly rare but have lacked in the past an adequate discussion in the literature, remaining ignored or misinterpreted. Preliminary calculations also predict sub-Nernstian responses and potential dips of a similar origin. The proper understanding of such phenomena will facilitate the development of new ISEs based on ionophores that form complexes of higher stoichiometries.
More Related Videos
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
09:18Measurement of Extracellular Ion Fluxes Using the Ion-selective Self-referencing Microelectrode Technique
Published on: May 3, 2015
Related Concept Videos
Potentiometry: Membrane Electrodes
Ion Exchange
Ion-Exchange Chromatography
Formation of Complex Ions
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Extraction: Advanced Methods