3D isotropic turbo spin-echo intermediate-weighted sequence with refocusing control in knee imaging: comparison study
Jung Min Seo1, Young Cheol Yoon, Jong Won Kwon
1Department of Radiology, School of Medicine, Sungkyunkwan University, Seoul, Korea.
The volume isotropic turbo spin echo acquisition (VISTA) sequence showed better knee joint tissue contrast for ligaments and menisci. Fast-field echo (FFE) sequences were superior for cartilage contrast, offering valuable insights for MRI protocols.
Area of Science:
- Radiology
- Medical Imaging
- Orthopedic Imaging
Background:
- Three-dimensional (3D) turbo spin-echo (TSE) MRI offers comparable diagnostic performance to 2D TSE for extremities.
- Previous studies have not compared 3D isotropic TSE intermediate-weighted (VISTA) and 3D fast-field echo (FFE) sequences for knee joint image quality.
Purpose of the Study:
- To compare the image quality of 3D VISTA and 3D FFE sequences for knee joint imaging.
- Evaluate tissue contrast differences between fluid-ligament, fluid-meniscus, and fluid-cartilage interfaces.
Main Methods:
- 10 healthy volunteers underwent 3.0 T knee MRI using VISTA and 3D FFE sequences.
- Musculoskeletal radiologists qualitatively assessed tissue contrast using a 4-point scale.
- Quantitative analysis included signal-to-noise ratio (SNR) and contrast ratios (CR) for specific tissue interfaces.
Main Results:
- VISTA demonstrated statistically superior qualitative tissue contrast for fluid-ligament (F-L) and fluid-meniscus (F-M) interfaces (P < 0.001).
- 3D FFE showed superior, though not statistically significant, qualitative contrast for fluid-cartilage (F-C).
- Quantitative analysis confirmed VISTA's higher SNR and superior CR for F-L and F-M, while 3D FFE excelled in F-C CR (P = 0.038).
Conclusions:
- The VISTA sequence offers superior subjective and quantitative tissue contrast for fluid-meniscus and fluid-ligament interfaces in knee MRI.
- The 3D FFE sequence provides superior contrast for the fluid-cartilage interface.