Characterization of ionic composition of TSP and PM10 during the Middle Eastern Dust (MED) storms in Ahvaz, Iran
Abbas Shahsavani1, Kazem Naddafi, Nematollah Jaafarzadeh Haghighifard
1Department of Health Engineering, School of Public Health, Tehran University of Medical Sciences, 16 Azar St., Enghelab Sq., Tehran, Iran. ashahsavani@gmail.com
Abstract:
Because of the recent frequent observations of major dust storms in southwestern cities in Iran such as Ahvaz, and the importance of the ionic composition of particulate matters regarding their health effects, source apportionment, etc., the present work was conducted aiming at characterizing the ionic composition of total suspended particles (TSP) and particles on the order of ∼10 μm or less (PM(10)) during dust storms in Ahvaz in April-September 2010. TSP and PM(10) samples were collected and their ionic compositions were determined using an ion chromatography. Mean concentrations of TSP and PM(10) were 1,481.5 and 1,072.9 μg/m(3), respectively. Particle concentrations during the Middle Eastern Dust (MED) days were up to four times higher than those in normal days. Ionic components contributed to only 9.5% and 11.3% of the total mass of TSP and PM(10), respectively. Crustal ions were most abundant during dust days, while secondary ions were dominant during non-dust days. Ca(2+)/Na(+) and Cl(-)/Na(+) ratios can be considered as the indicators for identification of the MED occurrence. It was found that possible chemical forms of NaCl, (NH(4))(2)SO(4), KCl, K(2)SO(4), CaCl(2), Ca(NO(3))(2), and CaSO(4) may exist in TSP. Correlation between the anionic and cationic components suggests slight anion and cation deficiencies in TSP and PM(10) samples, though the deficiencies were negligible.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Absorption Spectroscopy: Atomization Methods
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...
Precipitation Titration Curve: Analysis