Related Experiment Video
Updated: May 26, 2026

Magnetic Resonance Imaging Quantification of Pulmonary Perfusion using Calibrated Arterial Spin Labeling
Published on: May 30, 2011
An improved model for describing the contrast bolus in perfusion MRI
1Center for Biomedical Imaging, Department of Radiology, New York University School of Medicine, 660 First Avenue, New York, New York 10016, USA. Vishal.Patil@nyumc.org
Purpose:
Quantification of perfusion measurements using dynamic, susceptibility-weighted contrast-enhanced (DSC) MRI depends on estimating the size and shape of the tracer bolus. Typically, the bolus is described as a gamma variate function (GV) fitted to the bolus portion of tracer concentration time curve (CTC). However, the last point to fit is arbitrary which can lead to considerable variation in the fitted curve in the presence of noise. In this technical note, we present a model which takes into account recirculation explicitly and fits robustly to the entire CTC in the presence of noise.
Methods:
Signal data measurements from ten DSC MRI patients were fitted with our new model and a GV function using four different methods of estimating the end of the bolus. Estimates of the area under the curves (AUC) and first moments (FMs) of the bolus were compared at different noise levels.
Results:
The new model gave errors similar to or smaller than those of the most effective methods for fitting a GV.
Conclusions:
The single compartment recirculation (SCR) model is the most robust fitting technique with respect to noise both for bias and variability.
Related Concept Videos
Magnetic Resonance Imaging
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant, half-life,...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...
Compartment Models: Two-Compartment Model