Long-term Blood Pressure Measurement in Freely Moving Mice Using Telemetry
Published on: May 17, 2016
Blood pressure monitoring technique impacts hypertension treatment
Gretchen M Ray1, James J Nawarskas, Joe R Anderson
1University of New Mexico College of Pharmacy, MSC 09 5360, Albuquerque, NM 87131, USA. gray@salud.unm.edu
Background:
In 2005 the American Heart Association (AHA) released updated recommendations for blood pressure (BP) monitoring in order to ensure accurate BP measurements.
Objective:
To determine if current methods of BP assessment in an ambulatory clinic result in significantly different BP measurements than those obtained by following the AHA recommendations and if these BP differences impact treatment decisions.
Research Design:
Randomized prospective analysis.
Setting:
University of New Mexico Hospital Adult Internal Medicine clinic.
Patients:
Forty adults with hypertension
Methods:
Patient BPs were measured using both the traditional triage method and the AHA-recommended method in cross-over fashion in random order. Two complete medical profile summaries were then constructed for each patient: one for each BP measurement obtained by each technique. These profiles were then reviewed by a panel of providers who provided hypothetical hypertension treatment recommendations.
Results:
Individual BP results varied greatly between the two methods. SBP readings differed by ≥5 mmHg in either direction for 68% of patients while 78% of patient's DBP readings differed by ≥2 mmHg in either direction. Overall, 93% of patients had a BP difference of either ≥5 mmHg systolic or ≥2 mmHg diastolic. Five patients were determined to be at goal with the triage method, but were higher than their goal BP with the AHA method Significant differences were also seen in treatment recommendations for a given patient based on the differences seen between the two obtained BP readings. The number of patients with treatment variations between their two profiles ranged from 13% to 23% depending on the reviewing provider (p < 0.01 for all providers).
Conclusion:
Inaccurate BP assessment is common and may impact hypertension treatment decisions.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Hypertension III: Clinical Manifestations and Diagnostic Studies
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.