High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
High accuracy acoustic relative humidity measurement in duct flow with air
Wilhelm van Schaik1, Mart Grooten, Twan Wernaart
1Van Schaik Innovation Handling B.V., Glaslaan 2, Building SWA 1.032, 5616 LW, Eindhoven, The Netherlands. wvschaik@humitemp.com
Abstract:
An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0-12 m/s with an error of ± 0.13 m/s, temperature 0-100 °C with an error of ± 0.07 °C and relative humidity 0-100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.
More Related Videos
Related Concept Videos
Pipe Flowrate Measurement
The orifice meter is a simple,...
Measurement of Air Content in Concrete
The pressure method,...
Measurement of Fluid Pressure
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...