Related Experiment Video
Updated: May 26, 2026

Reliability of Artificial Intelligence-Based Cone Beam Computed Tomography Integration with Digital Dental Images
Published on: February 23, 2024
Comparative assessment of subjective image quality of cross-sectional cone-beam computed tomography scans
Kivanç Kamburoğlu1, Sema Murat, Eray Kolsuz
1Department of Dentomaxillofacial Radiology, Faculty of Dentistry, Ankara University, Ankara, Turkey. dtkivo@yahoo.com
Abstract:
Since the introduction of cone-beam computed tomography (CBCT), several novel systems with different technical specifications and settings have become commercially available. Therefore, it is essential to evaluate CBCT systems for differences in the subjective quality of images obtained for various dental procedures. We evaluated the subjective image quality of cross-sectional scans obtained from various CBCT systems. Images of three cadaver mandibles were obtained from four different CBCT units: 1) Veraviewepocs 3D 40 × 40 mm field of view (FOV) (voxel size: 0.125 × 0.125 × 0.125 mm), 2) Iluma, low-resolution (voxel size: 0.3 × 0.3 × 0.3 mm), 3) Kodak, 50 × 3.7 cm FOV (voxel size: 0.076 × 0.076 × 0.076 mm), and 4) Vatech 12 × 8.5cm FOV (voxel size: 0.160 × 0.160 × 0.160 mm). We assessed subjective image quality and the visibility of 10 specific features, namely, caries, amalgam restoration, final implant drill, root canal filling, metal crown, mandibular canal, mental foramen, tooth (periodontal ligament space and lamina dura), trabecular pattern, and soft tissue. Images were viewed and scored by five calibrated observers, and image quality was ranked from best to worst. The Veraviewepocs 3D had the highest quality images for most of the assessed features, whereas the Iluma low-resolution scans were rated as the lowest quality images.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET