Related Experiment Video
Updated: May 26, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Feasibility and variability of measuring the Lung Clearance Index in a multi-center setting
Susanne I Fuchs1, Helmut Ellemunter, Johannes Eder
1Marien Hospital Wesel, Children's Hospital and Research Institute, Wesel, Germany.
Abstract:
The Lung Clearance Index (LCI) is superior to spirometry in detecting early lung disease in cystic fibrosis (CF) and correlates with structural lung changes seen on CT scans. The LCI has the potential to become a novel outcome parameter for clinical and research purposes. However longitudinal studies are required to further prove its prognostic value. Multi-center design is likely to facilitate realization of such studies. Therefore the aim of the present study was to assess multi-center feasibility and inter-center variability of LCI measurements in healthy children and adolescents. Comparative measurements were performed in unselected patients with CF to confirm previous single-center results. LCI measurements were performed in eight centers using the EasyOne Pro, MBW Module (ndd Medical Technologies, Zurich, Switzerland). The overall success rate for LCI measurements was 75.5%, leaving 102/151 measurements in healthy volunteers and 139/183 measurements in patients with CF for final analysis. Age ranged between 4 and 24 years. Mean LCI (range of means among centers) was 6.3 (6.0-6.5) in healthy volunteers and thus normal. Inter-center variability of center means was 2.9%, ANOVA including Schffé procedure demonstrated no significant inter-center differences (P > 0.05). Mean LCI (range of means among centers) was 8.2 (7.4-8.9) in CF and thus abnormal. Our study demonstrates good multi-center feasibility and low inter-center variability of the LCI in healthy volunteers when measured with the EasyOne Pro MBW module. Our data confirm published LCI data in CF. However, central coordination, quality control, regular training, and supervision during the entire study appear essential for successfully performing multi-center trials.
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
Clearance Models: Noncompartmental Models
The noncompartmental approach capitalizes on extensive sampling data, correlating the volume of distribution to systemic exposure and the administered dosage. This method enables...