Related Experiment Video
Updated: May 26, 2026

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
CMR imaging of edema in myocardial infarction using cine balanced steady-state free precession
Andreas Kumar1, Nirat Beohar, Jain Mangalathu Arumana
1Heart and Lung Institute, Laval University, Québec City, Québec, Canada.
Objectives:
The aim of this study was to investigate the capabilities of balanced steady-state free precession (bSSFP) cardiac magnetic resonance imaging as a novel cine imaging approach for characterizing myocardial edema in animals and patients after reperfused myocardial infarction.
Background:
Current cardiac magnetic resonance methods require 2 separate scans for assessment of myocardial edema and cardiac function.
Methods:
Mini-pigs (n = 13) with experimentally induced reperfused myocardial infarction and patients with reperfused ST-segment elevation myocardial infarction (n = 26) underwent cardiac magnetic resonance scans on days 2 to 4 post-reperfusion. Cine bSSFP, T2-weighted short TI inversion recovery (T2-STIR), and late gadolinium enhancement were performed at 1.5-T. Cine bSSFP and T2-STIR images were acquired with a body coil to mitigate surface coil bias. Signal, contrast, and the area of edema were compared. Additional patients (n = 10) were analyzed for the effect of microvascular obstruction on bSSFP. A receiver-operator characteristic analysis was performed to assess the accuracy of edema detection.
Results:
An area of hyperintense bSSFP signal consistent with edema was observed in the infarction zone (contrast-to-noise ratio: 37 ± 13) in all animals and correlated well with the area of late gadolinium enhancement (R = 0.83, p < 0.01). In all patients, T2-STIR and bSSFP images showed regional hyperintensity in the infarction zone. Normalized contrast-to-noise ratios were not different between T2-STIR and bSSFP. On a slice basis, the volumes of hyperintensity on T2-STIR and bSSFP images correlated well (R = 0.86, p < 0.001), and their means were not different. When compared with T2-STIR, bSSFP was positive for edema in 25 of 26 patients (96% sensitivity) and was negative in all controls (100% specificity). All patients with microvascular obstruction showed a significant reduction of signal in the subendocardial infarction zone compared with infarcted epicardial tissue without microvascular obstruction (p < 0.05).
Conclusions:
Myocardial edema from ST-segment elevation myocardial infarction can be detected using cine bSSFP imaging with image contrast similar to T2-STIR. This new imaging approach allows evaluation of cardiac function and edema simultaneously, thereby reducing patient scan time and increasing efficiency. Further work is necessary to optimize edema contrast in bSSFP images.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Acute Coronary Syndrome III: Diagnostic Studies
Magnetic Resonance Imaging