Clinical implications of internal carotid artery flow impairment caused by filter occlusion during carotid artery
O-K Kwon1, S H Kim, E A Jacobsen
1Clinical Neuroscience Center, Seoul National University Bundang Hospital, Bundang, South Korea.
Insights
Filter occlusion during carotid artery stenting (CAS) is common, especially in severe stenosis. While it can temporarily halt internal carotid artery (ICA) flow, it resolves quickly upon filter removal and does not worsen patient outcomes.
Area of Science:
- Interventional Neuroradiology
- Vascular Surgery
- Cardiovascular Research
Background:
- Cerebral embolic protection devices (EPDs) are used during carotid artery stenting (CAS) to preserve internal carotid artery (ICA) flow.
- Filter occlusion, leading to ICA flow arrest, is a potential complication of EPD use during CAS.
Purpose of the Study:
- To describe the angiographic, clinical, and histopathologic features of filter occlusion during CAS.
- To evaluate the incidence and impact of filter occlusion on patient outcomes.
Main Methods:
- Sixty-one patients with cervical carotid stenosis undergoing CAS with a specific filter device were evaluated.
- Dual antiplatelet therapy and full heparinization were administered; pre- and post-stent dilations were performed.
- Filters were inspected for debris, and histology was obtained if occlusion occurred.
Main Results:
- Filter occlusion occurred in 9.8% of patients, predominantly in those with severe stenosis.
- Occlusion typically happened after stent deployment or prestent dilation and resolved immediately upon filter removal.
- Histopathology revealed fibrin as the primary occlusive material; no significant difference in diffusion MRI was noted between occluded and non-occluded groups.
Conclusions:
- ICA flow arrest due to filter occlusion during CAS is a relatively frequent event, particularly in severe carotid stenosis.
- Filter occlusion is transient, resolves rapidly with filter removal, and does not appear to negatively impact neurological outcomes.
Background And Purpose:
Membrane filters are EPDs, which preserve ICA flow during CAS. However, ICA flow arrest may occur with filter use. This report describes the angiographic, clinical, and histopathologic features of the filter occlusion.
Materials And Methods:
Sixty-one consecutive patients with cervical carotid stenosis treated by CAS by using a single type of filter device were evaluated. All patients were on dual antiplatelet treatment and fully heparinized. Prestent dilation was performed in all patients. Poststent dilation was performed in 15 patients. Control angiograms were obtained and evaluated after each step of the CAS procedure. All filters were inspected for debris, and if present, histology was obtained.
Results:
CAS was successfully performed in all cases with <20% residual stenosis. Filter occlusion occurred in 6 patients (9.8%). It developed immediately after stent deployment in 4, and after a second prestent dilation in 2. Five of the 6 had severe carotid stenosis. In all patients, filter withdrawal led to immediate and complete restoration of ICA flow. In 1 patient, acute embolic M1 occlusion occurred immediately after filter withdrawal but was successfully treated with thrombolysis. None of filter-occlusion group had permanent neurologic deficits. Gross and microscopic examinations demonstrated that the pores of the filters were occluded mainly by fibrin. Postoperative diffusion MR imaging revealed no difference between filter-occlusion and non-filter-occlusion groups.
Conclusions:
ICA flow arrest due to filter occlusion during CAS is relatively common and occurs more frequently in severe stenosis. It resolves rapidly after filter removal and does not appear to worsen outcome.
Related Concept Videos
Ischemic Stroke l: Introduction
Arteries of the Head and Neck
The internal carotid arteries supply blood to the anterior portion of the cerebrum. They enter the...
Transient Ischemic Attack l: Introduction
Ischemic Stroke ll: Pathophysiology
