Related Experiment Video
Updated: May 26, 2026

The Development of Lyophilized Loop-mediated Isothermal Amplification Reagents for the Detection of Coxiella burnetii
Published on: April 18, 2016
Loop-mediated isothermal amplification compared to real-time PCR and enzyme immunoassay for toxigenic Clostridium
Bobby L Boyanton1, Preethi Sural, Caroline R Loomis
1Shanghai Key Laboratory of Tuberculosis, Shanghai Pulmonary Hospital, Medical School, Tongji University, Shanghai, China. bobby.boyanton@beaumont.edu
Abstract:
Clostridium difficile infection is the primary cause of health care-associated diarrhea. While most laboratories have been using rapid antigen tests for detecting C. difficile toxins, they have poor sensitivity; newer molecular methods offer rapid results with high test sensitivity and specificity. This study was designed to compare the performances of two molecular assays (Meridian illumigene and BD GeneOhm) and two antigen assays (Wampole Quik Chek Complete and TechLab Tox A/B II) to detect toxigenic C. difficile. Fecal specimens from hospitalized patients (n = 139) suspected of having C. difficile infection were tested by the four assays. Nine specimens were positive and 109 were negative by all four methods. After discrepant analysis by toxigenic culture (n = 21), the total numbers of stool specimens classified as positive and negative for toxigenic C. difficile were 21 (15%) and 118 (85%), respectively. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were as follows: GeneOhm (95.2%, 100%, 100%, and 99.2%), illumigene (95.2%, 96.6%, 83.3%, and 99.2%), Tox A/B II (52.4%, 97.5%, 78.6%, and 92.4%), and Quik Chek Complete (47.6%, 100%, 100%, and 91.9%). The illumigene assay performed comparably to the GeneOhm assay with a slight decrease in test specificity; the sensitivities of both far exceeded those of the antigen assays. The clinical characteristics of the concordant and discrepant study patients were similar, including stool consistency and frequency. In the era of rapid molecular-based tests for toxigenic C. difficile, toxin enzyme immunoassays (EIAs) should no longer be considered the standard of care.
More Related Videos
06:11Rapid Detection of Bacterial Pathogens Causing Lower Respiratory Tract Infections via Microfluidic-Chip-Based Loop-Mediated Isothermal Amplification
Published on: March 29, 2024
06:18Multiplexed Isothermal Amplification Based Diagnostic Platform to Detect Zika, Chikungunya, and Dengue 1
Published on: March 13, 2018