Multimodal Volumetric Retinal Imaging by Oblique Scanning Laser Ophthalmoscopy (oSLO) and Optical Coherence Tomography (OCT)
Published on: August 4, 2018
High-speed cross-sectional imaging of valuable documents using common-path swept-source optical coherence tomography.
1Research and Development Center, GLORY Ltd., 1-3-1 Shimoteno, Himeji, Hyogo 670-8567, Japan.
Common-path swept-source optical coherence tomography (SS-OCT) enables high-speed document imaging for security checks. This study confirms SS-OCT
Area of Science:
- Optical Engineering
- Metrology
- Document Security
Background:
- Common-path swept-source optical coherence tomography (SS-OCT) offers potential for high-speed and stable optical coherence tomography (OCT) systems.
- Assessing the security features of valuable documents necessitates high-speed imaging techniques capable of capturing cross-sectional details.
Purpose of the Study:
- To investigate the efficacy of a common-path SS-OCT system for cross-sectional imaging of documents.
- To evaluate the impact of high transport speeds on the performance of SS-OCT for document security analysis.
Main Methods:
- An SS-OCT system utilizing a swept source (1335 nm center wavelength, 50 kHz sweep repetition rate) was employed.
- Document samples were translated at speeds up to 2000 mm/s.
- The influence of transport speed on depth resolution and signal intensity was experimentally assessed.
Main Results:
- The common-path SS-OCT system demonstrated capability for cross-sectional imaging of documents at high speeds.
- Experimental results showed signal degradation that aligned with theoretical predictions as transport speed increased.
- Depth resolution and signal intensity were evaluated under various high-speed translation conditions.
Conclusions:
- Common-path SS-OCT is a viable technology for high-speed imaging of documents to verify security features.
- The observed signal degradation at high speeds is consistent with theoretical models, validating the system's performance.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Confocal Fluorescence Microscopy