X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Principles of multidetector-row computed tomography. Part 2: determinants of radiation exposure and current
1Abteilung für Diagnostische und Interventionelle Radiologie, Universitätsklinikum Heidelberg, Heidelberg, Deutschland. wolfram.stiller@med.uni-heidelberg.de
Abstract:
In the field of multidetector-row computed tomography (MDCT) technical improvements have constantly extended the range of clinical applications and made new radiodiagnostic indications accessible. Whereas previous technical improvements were primarily aimed at the imaging of anatomy with high spatial and temporal resolution, nowadays a trend towards quantitative and functional imaging using computed tomography (CT) beyond the pure depiction of morphology is on the horizon: Currently the focus of technical developments is in the domain of spectral (energy-resolved) CT imaging and in the introduction of very wide multi-row detectors with large z-coverage. In addition, there is great interest in technical approaches for reducing radiation exposure of the patients caused by (spiral) MDCT, as the increasing range of its clinical applications as well as some of the recent technical advances involve the risk of increased radiation exposure. The use of iterative image reconstruction techniques in MDCT represents a particularly promising technical approach for the reduction of radiation exposure.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
14:19A Basic Positron Emission Tomography System Constructed to Locate a Radioactive Source in a Bi-dimensional Space
Published on: February 1, 2016
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
X-ray Imaging