Conclusions:
An abrupt change in the venous caliber, producing turbulent flow, may be a cause of pulsatile tinnitus (PT). The largest area/smallest area (L/S) ratio >4.75 may be a criterion indicating abrupt caliber change and causing PT.
Objectives:
Contrast-enhanced CT is recommended as an initial work-up modality in PT. But, in the majority of cases, no definite pathology can be found, even after extensive work-up. In these cases, the unilateral dominant venous system may be the cause of PT. The aim of this study was to compare, through 3D-reformatted images of the intracranial venous system, the volume, cross-sectional area, and caliber changes in patients with PT and normal controls.
Methods:
This was a cross-sectional study set in a tertiary referral center. Eleven patients (11 unilateral PT ears) and 12 normal control ears were enrolled. All the subjects were confirmed with normal CT angiography findings. The intracranial venous structure was three-dimensionally reconstructed. Three areas with the largest and the smallest dimension were selected for further analysis: the transverse sinus (T), isthmus (I), and the jugular bulb (B). The total volume, cross-sectional area, and cross-sectional area ratios of the three areas were compared in the PT group and the normal control group.
Results:
The L/S ratio was significantly increased in the PT group (5.01), compared with the control group (3.42). When the threshold value of the L/S ratio was assessed by the ROC method, 4.75 seemed to be the significant dissecting point. The sensitivity of this method was 0.64 and the specificity was 0.83.
Related Concept Videos
Veins of Head and Neck
On the other hand, the vertebral veins, unlike their arterial counterparts, are not primarily responsible for brain drainage. Instead, they drain the cervical vertebrae, spinal cord, and some small...
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Venous Return
What is Venous Return?
Venous return refers to the rate at which blood flows back to the heart from the body's peripheral veins. It's an integral part of the circulatory system as it...
Veins of Upper Limbs
The deep venous system is primarily composed of the ulnar and radial veins. The ulnar vein, which drains the fingers through the superficial palmar venous arches, and the radial vein, which serves the palms via the deep palmar...
Venous Thrombosis III: Interprofessional Care