Related Experiment Video
Updated: May 26, 2026

Laser Doppler: A Tool for Measuring Pancreatic Islet Microvascular Vasomotion In Vivo
Published on: March 8, 2018
Hemorheology and heart rate variability in patients with diabetes mellitus type 2
Irena Velcheva1, Petar Damianov, Stefka Mantarova
1Department of Neurology, Medical University, Sofia, Bulgaria. velchevairena@gmail.com
Our study aimed to investigate the relationship between hemorheological parameters and heart rate variability (HRV) in patients with diabetes mellitus type 2. Hemorheological variables, including hematocrit (Ht), fibrinogen (Fib), whole blood (WBV) and plasma viscosity (PV) at shear rates of 0.0237 s(-1) to 128.5 s(-1) were examined in 20 patients with diabetes mellitus type 2 and in 10 control subjects. They all underwent non-invasive short-term monitoring of heart rate at rest and after passive head-up tilt. Measurement of the R-R intervals and calculation of the time domain parameters and the power spectral data were performed by our softwear, using fast Fourier transformation. Significant increase of Fib and WBV in the patients in comparison to controls was found within the range of shear rates 0.0237 s(-1) to 128.5 s(-1). In the diabetic patients parallel decrease of the total power (TP), the low frequency spectral power (LF) and of the mean RR and mild increase of the low frequency-high frequency ratio (LF/HF) at rest were established. This tendency was kept after the passive tilt. In patients with diabetes mellitus type 2 the increased blood viscosity was associated with reduced HRV.
Our study aimed to investigate the relationship between hemorheological parameters and heart rate variability (HRV) in patients with diabetes mellitus type 2. Hemorheological variables, including hematocrit (Ht), fibrinogen (Fib), whole blood (WBV) and plasma viscosity (PV) at shear rates of 0.0237 s(-1) to 128.5 s(-1) were examined in 20 patients with diabetes mellitus type 2 and in 10 control subjects. They all underwent non-invasive short-term monitoring of heart rate at rest and after passive head-up tilt. Measurement of the R-R intervals and calculation of the time domain parameters and the power spectral data were performed by our softwear, using fast Fourier transformation. Significant increase of Fib and WBV in the patients in comparison to controls was found within the range of shear rates 0.0237 s(-1) to 128.5 s(-1). In the diabetic patients parallel decrease of the total power (TP), the low frequency spectral power (LF) and of the mean RR and mild increase of the low frequency-high frequency ratio (LF/HF) at rest were established. This tendency was kept after the passive tilt. In patients with diabetes mellitus type 2 the increased blood viscosity was associated with reduced HRV.
Related Concept Videos
Type II Diabetes II: Pathophysiology
Diabetic Retinopathy
Type I Diabetes II: Pathophysiology
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Diabetes Mellitus: Type 2 and Gestational
Type II Diabetes Mellitus III: Clinical Manifestations and Diagnosis

