Digital Home-Monitoring of Patients after Kidney Transplantation: The MACCS Platform
Published on: April 12, 2021
Ambulatory blood pressure monitoring in solid organ transplantation
1St. Michael's Hospital and University of Toronto, Toronto, ON, Canada. prasadr@smh.ca
Abstract:
Solid organ transplant recipients are at an increased risk for hypertension and cardiovascular disease. To assist in their management, 24-h ambulatory blood pressure monitoring (ABPM) has become increasingly used in both clinical research settings and practice. ABPM has been used to better define post-transplant hypertension incidence and prevalence in different solid organ transplantation populations. ABPM provides additional information on cardiovascular risk beyond that obtained by clinic-based readings, based on its ability to assess 24-h blood pressure (BP) load, detect nocturnal non-dipping, and predict target organ damage. It has provided some assurance about the safety of living kidney donation. Information from ABPM can be used to guide living kidney donor selection, and because ABPM-related data has been correlated with clinically important kidney and heart transplant recipient outcomes, it may be a valuable adjunct in their management. Despite these advantages, barriers to wider use of ABPM include expense, clinical inertia in hypertension management, lack of prospective clinical trial data, and clinical problems that compete with hypertension for attention such as acute or chronic allograft dysfunction. The increasing amount of research and clinical use for ABPM may allow for closer assessment and intervention to help address the increased cardiovascular risk faced by many solid organ transplant recipients.
Related Concept Videos
Kidney Transplant III: Nursing Management
Kidney Transplant I: Introduction
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Kidney Transplant II: Surgical Procedure
Pre-Procedural Guidelines for Assessing Blood Pressure
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...