Abstract:
The congener patterns of mono- to octa-chlorinated dibenzo-p-dioxins (PC(1-8)DD), dibenzofurans (PC(1-8)DF), naphthalenes (PC(1-8)N), mono- to deca-chlorinated biphenyls (PC(1-10)B), di- to hexa-chlorinated benzenes (PC(2-6)Bz) and mono- to penta-chlorinated phenols (PC(1-5)Ph) in flue gas samples collected simultaneously at 450°C, 300°C and 200°C in the post-combustion zone during waste incineration in a laboratory-scale reactor in a previous study, were in this study evaluated using principal component analysis (PCA). To our knowledge this is the most comprehensive chemical and multivariate analysis to date of the thermal formation of dioxins. The PCA indicated that different formation pathways occur in the temperature regions 450-300°C and 300-200°C, and reflected a chlorination effect of PCDF and PCDD between 450°C and 200°C which could not be discerned or was less pronounced for the other compound groups. Toxic equivalents (TEQs) of PCDDs, PCDFs and PCBs, as well as total TEQ values (TEQ(Total)) were also calculated, and correlations between changes in levels of specific congeners and the TEQs were explored in the PCA. Levels of four HxCDF congeners and 1,2,3,4,8-, 1,2,3,7,8-PeCDF and 2,3,4,7,8-PeCDF showed the strongest correlations with TEQ(Total) (R(2)≥0.9). In addition, levels of 1,2,4-TriCBz correlated strongly with TEQ(Total) (R(2)>0.7), supporting previous reports that it may be a potential indicator of the TEQ.
Related Concept Videos
Multiple Pipe Systems
Series Configuration
In a series configuration, fluid flows sequentially from one pipe...
General Characteristics of Pipe Flow II
The distance to reach a fully developed flow is called the entrance length and depends on the flow...
General Characteristics of Pipe Flow I
The classification of fluid...
Fast Decoupled and DC Powerflow
Heating and Cooling Curves
For instance, the addition of heat raises the temperature of a solid; the amount of heat absorbed depends on the heat capacity of the solid (q = mcsolidΔT). According to thermochemistry, the relation between the amount of heat absorbed or released by a substance, q, and its...
Single Pipe Systems