Related Experiment Video
Updated: May 26, 2026

In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
Imaging Natural Occlusal Caries Lesions with Optical Coherence Tomography
Shane M Douglas1, Daniel Fried, Cynthia L Darling
1University of California, San Francisco, San Francisco, CA 94143-0758.
None:
Several studies have demonstrated that polarization-sensitive optical coherence tomography (PS-OCT) can be used to nondestructively measure the severity of demineralization in the important occlusal surfaces. The purpose of this study was to assess the potential of PS-OCT and OCT methods for the measurement of the depth of natural occlusal carious lesions. Teeth were screened for potential occlusal lesions using near infrared imaging (NIR). A PS-OCT system operating at 1310-nm was used to acquire polarization resolved images of the area of interest on the occlusal surface. The teeth were serial sectioned to 200 microm thickness and examined with polarized light microscopy (PLM) and Transverse Microradiography (TMR) for comparison. The lesion depth measured nondestructively with PS-OCT was compared to the lesion depth measured with PLM and TMR to assess the performance of these methods and determine if polarization sensitivity is required. The lesion depth measured using OCT correlated well with the lesion depths measured with TMR and PLM. Although polarization sensitivity provided better contrast it was not necessary to have polarization sensitivity to identify deep occlusal lesions.
More Related Videos
06:15Anterior High-Resolution Optical Coherence Tomography in the Diagnosis and Therapeutic Monitoring of Ocular Surface Squamous Neoplasia
Published on: August 9, 2024
09:56Automated 3D Optical Coherence Tomography to Elucidate Biofilm Morphogenesis Over Large Spatial Scales
Published on: August 21, 2019
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...