Related Experiment Video
Updated: May 25, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Influence of continuous renal replacement therapy on cardiac output measurement using thermodilution techniques
D Heise1, M Faulstich, O Mörer
1Department of Anaesthesiology, Emergency and Critical Care Medicine, University of Göttingen, Göttingen, Germany. dheise1@gwdg.de
Background:
Acute renal failure (ARF) ranks among the most frequent complications in critically ill patients and continuous renal replacement therapy (CRRT) is a typical treatment regimen in intensive care patients. Contributing factors to ARF, such as septic shock and hemodynamic instability require extended hemodynamic monitoring, and the simultaneous use of CRRT and cardiac output measurement is common. In view of this, a systematic analysis of the interaction between CRRT and cardiac output measurements by thermodilution is warranted. Cardiac output (CO) is commonly measured with thermodilution-based methods in critically ill patients. The methods are accurate but the measurements are affected by inconstant indicator volumes or changes in blood temperature. Because continuous renal replacement therapy (CRRT) may alter blood volume and temperature, we investigated its effect on thermodilution-based CO measurement.
Methods:
Thirty-two intensive care patients with both CRRT and CO monitoring were studied. Hemodynamic parameters were first measured in quintuple with bolus injections of cold saline during CRRT. Further five measurements were performed after CRRT had been shut off, and a final five measurements were performed after it had been restarted. Fifty measurement series were performed in patients with a pulmonary artery catheter and 25 in patients using a transpulmonary thermodilution method (PiCCO®).
Results:
The first measurements in each series after switching CRRT off or on deviated most markedly from the average. When these measurements were excluded, the averaged CO values with and without CRRT differed significantly but by <7% (P<0.05).
Conclusion:
Substantial measurement error was only observed immediately after CRRT was switched off or on. Subsequent CO measurements did not depend on the CRRT status. Interrupting CRRT before measuring CO is not generally recommended, however, if interrupted, it is crucial to wait for blood temperature to reach a steady state before initiating the first measurements.
Related Concept Videos
Continuous Renal Replacement Therapy
Extracorporeal Removal of Drugs: Continuous Renal Replacement Therapy
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Heart Failure VI: Adjunct Therapies