Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
[Contribution of automatic sphygmomanometers for one-time measurement of blood pressure]
Abstract:
Due to high intra-individual variability of arterial blood pressure, single measurements provide only estimates of true actual values. Two or three recordings made in sequence in one or a few minutes' intervals are recommended in some clinical studies of antihypertensive therapy, with the aim of decreasing the variability. In order to examine the value of repeated measurements made on one occasion, four sequential resting recordings of blood pressure and heart rate made in one minute intervals with the automatic oscillometric Nippon Colin BP-103N sphygmomanometer were evaluated in 66 subjects, using the analysis of variance methods. Means of three recordings showed a significantly lower variability than single measurements (almost by one half), while the difference between three and four readings was not significant. The Page's rank test revealed that the first measurements are not uniformly the highest ones, and therefore the medians of three readings made in sequence are recommended as characteristics of resting blood pressure. An advantage of the oscillometric method is the possibility of measuring mean arterial pressure. The recorded values were significantly higher than those calculated from the systolic and diastolic pressures according to the current formula, being situated between one third and one half of the pulse pressure. The intra-individual coefficient of variation of the recorded mean arterial pressure was comparable with that of systolic and significantly lower than that of diastolic pressure.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure