Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Respiratory Volumes01:15

Respiratory Volumes

Respiratory volumes are crucial metrics, meticulously measured to quantify the air exchanged in and out of the lungs during various phases of the breathing cycle. These precise measurements are vital for assessing lung function, diagnosing respiratory conditions, and monitoring overall respiratory health. Each parameter provides specific insights into the mechanics of breathing and the functional capacity of the lungs.
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen01:16

Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen

Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Improving Glycemic Control Through Population-Based Strategies: A Case-Control Study Within a Large Health System.

Journal of general internal medicine·2026
Same author

Entropy-Modulated Oxide-Metal Catalyst Architectures for Direct Ammonia Protonic Ceramic Fuel Cells.

Nano-micro letters·2026
Same author

Interfacially Reinforced Crosslinked Binder with Structural Integrity for Stable Micro-Sized Silicon Anodes in All-solid-state Batteries.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

A Proton-Intercalation Pathway Realizes Long-Life Manganese-Ion Hybrid Batteries With Layered KV<sub>3</sub>O<sub>8</sub>.

Advanced science (Weinheim, Baden-Wurttemberg, Germany)·2026
Same author

Real-Time Parking Space Management System Based on a Low-Power Embedded Platform.

Sensors (Basel, Switzerland)·2025
Same author

Exploring Metalloproteome Remodeling in Calprotectin-Stressed <i>Acinetobacter baumannii</i> Using Chemoproteomics.

ACS chemical biology·2025
Same journal

Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
See all related articles

Related Experiment Video

Updated: May 25, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Published on: January 8, 2019

A convenient pulmonary volume and flow detection system.

Myeongheon Sim1, Minyong Kim, Incheol Jeong

  • 1Department of Biomedical Engineering, Yonsei University, 234 maeji heung-up, Wonju, Kangwon, Republic of Korea. bmesim@gmail.com

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
|January 19, 2012
PubMed
Summary
This summary is machine-generated.

A new impedance pulmonary function measurement system (IPFS) offers a convenient alternative to traditional spirometric pulmonary function tests (PFTs). This novel system accurately measures key respiratory parameters using only hand electrodes.

More Related Videos

Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
10:02

Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow

Published on: April 29, 2011

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
05:56

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit

Published on: September 6, 2024

Related Experiment Videos

Last Updated: May 25, 2026

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
08:25

Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship

Published on: January 8, 2019

Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow
10:02

Characterization of the Isolated, Ventilated, and Instrumented Mouse Lung Perfused with Pulsatile Flow

Published on: April 29, 2011

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
05:56

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit

Published on: September 6, 2024

Area of Science:

  • Biomedical Engineering
  • Respiratory Physiology
  • Medical Device Development

Background:

  • Pulmonary Function Tests (PFTs) are crucial for assessing respiratory health but often involve cumbersome spirometry.
  • Existing PFT methods can be restrictive, posing challenges for certain patient populations or settings.
  • There is a need for more accessible and convenient methods for measuring pulmonary function.

Purpose of the Study:

  • To develop a novel Impedance Pulmonary Function Measurement System (IPFS) as a convenient alternative to spirometric PFT.
  • To validate the accuracy and reliability of the IPFS in measuring pulmonary function parameters.
  • To assess the potential of IPFS for detecting key indicators of lung function, such as volume and flow rates.

Main Methods:

  • Development of an IPFS utilizing tetrapolar electrodes for measurements via hand contact only.
  • Extraction of respiratory impedance changes (AC values) from body impedance (DC values) during respiration.
  • Comparison of continuous waveforms from IPFS and spirometric PFT using Pearson linear correlation coefficients (p < 0.01).
  • Evaluation of IPFS for measuring specific pulmonary function parameters like FEV(1)/FVC Ratio and PEF.

Main Results:

  • The IPFS demonstrated significant linear correlation (p < 0.01) with spirometric PFT for both volume and flow measurements.
  • Measurements obtained from the IPFS accurately reflected key pulmonary function parameters, including FEV(1)/FVC Ratio and PEF.
  • The system successfully yielded changes in impedance corresponding to lung volume and airflow.

Conclusions:

  • The developed Impedance Pulmonary Function Measurement System (IPFS) is a viable and convenient tool for assessing pulmonary function.
  • IPFS offers a promising non-invasive method for measuring respiratory parameters, potentially overcoming limitations of traditional spirometry.
  • Further research can explore the widespread clinical application of IPFS for respiratory health monitoring.