Related Experiment Video
Updated: May 25, 2026

Using Adeno-associated Virus as a Tool to Study Retinal Barriers in Disease
Published on: April 19, 2015
Avastin doesn't blind people, people blind people
Serafin Gonzalez1, Philip J Rosenfeld, Michael W Stewart
1Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL 33136, USA.
Purpose:
To review the appropriate preparation of bevacizumab for intravitreal injection by compounding pharmacies with specific recommendations designed to prevent microbial contamination.
Design:
Perspective.
Methods:
A review and discussion of compounding issues with supporting literature, clinical experience, illustrations, and expert opinion.
Results:
Closer examination of the events surrounding the recent clusters of infectious endophthalmitis cases occurring after the intravitreal injection of bevacizumab suggest that the vision loss is not the result of the drug or the injection technique, but rather of the compounding procedures used to prepare the syringes containing the bevacizumab. Noncompliance with recognized standards and poor aseptic technique are the most likely causes of these outbreaks. The key to preventing these catastrophic occurrences depends on the implementation of and strict adherence to United States Pharmacopoeia Chapter 797 requirements.
Conclusions:
Recommendations arising from a root cause analysis of infectious endophthalmitis outbreaks should focus on the procedures used by pharmacies to compound bevacizumab. Microbial contamination of bevacizumab-containing syringes prepared from the same vial of drug can be avoided by using a single vial of bevacizumab for each eye or by following strict adherence to United States Pharmacopoeia Chapter 797 requirements when compounding a single vial of bevacizumab into multiple syringes.
Related Concept Videos
Blinding
Blind Procedures
Unrenewable Cells
Photoreceptors
The retina is composed of several layers and contains specialized cells called photoreceptors. The photoreceptors (rods and cones) change their membrane potential when stimulated by light energy. There are two types of photoreceptors—rods and cones—which differ in the shape of their outer...
Hemodialysis I: Introduction
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...