Related Experiment Video
Updated: May 25, 2026

A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
Chemometrics optimization of six antihistamines separations by capillary electrophoresis with
Derong Zhu1, Xia Li, Jinying Sun
1Department of Medicinal Chemistry and Pharmaceutical Analysis, Guangdong Medical College, Dongwan, Guangdong, China.
Abstract:
This work expanded the knowledge of the use of chemometric experimental design in optimizing of six antihistamines separations by capillary electrophoresis with electrochemiluminescence detection. Specially, central composite design was employed for optimizing the three critical electrophoretic variables (Tris-H(3)PO(4) buffer concentration, buffer pH value and separation voltage) using the chromatography resolution statistic function (CRS function) as the response variable. The optimum conditions were established from empirical model: 24.2mM Tris-H(3)PO(4) buffer (pH 2.7) with separation voltage of 15.9 kV. Applying theses conditions, the six antihistamines (carbinoxamine, chlorpheniramine, cyproheptadine, doxylamine, diphenhydramine and ephedrine) could be simultaneous separated in less than 22 min. Our results indicate that the chemometrics optimization method can greatly simplify the optimization procedure for multi-component analysis. The proposed method was also validated for linearity, repeatability and sensitivity, and was successfully applied to determine these antihistamine drugs in urine.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Electrophoresis: Overview
There...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Capillary Electrophoresis: Instrumentation
Ion-Exchange Chromatography
High-Performance Liquid Chromatography: Types of Detectors