Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
Comparison of image quality in computed laminography and tomography
Feng Xu1, Lukas Helfen, Tilo Baumbach
1Institute for Synchrotron Radiation, Karlsruhe Institute of Technology, Germany.
Abstract:
In computed tomography (CT), projection images of the sample are acquired over an angular range between 180 to 360 degrees around a rotation axis. A special case of CT is that of limited-angle CT, where some of the rotation angles are inaccessible, leading to artefacts in the reconstrucion because of missing information. The case of flat samples is considered, where the projection angles that are close to the sample surface are either i) completely unavailable or ii) very noisy due to the limited transmission at these angles. Computed laminography (CL) is an imaging technique especially suited for flat samples. CL is a generalization of CT that uses a rotation axis tilted by less than 90 degrees with respect to the incident beam. Thus CL avoids using projections from angles closest to the sample surface. We make a quantitative comparison of the imaging artefacts between CL and limited-angle CT for the case of a parallel-beam geometry. Both experimental and simulated images are used to characterize the effect of the artefacts on the resolution and visible image features. The results indicate that CL has an advantage over CT in cases when the missing angular range is a significant portion of the total angular range. In the case when the quality of the projections is limited by noise, CT allows a better tradeoff between the noise level and the missing angular range.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Three-Dimensional Microscopy in Microbiology