Can changes in arterial pressure be used to detect changes in cardiac index during fluid challenge in patients with
Charalampos Pierrakos1, Dimitrios Velissaris, Sabino Scolletta
1Department of Intensive Care, Erasme University Hospital, Université Libre de Bruxelles, Route de Lennik 808, 1070 Brussels, Belgium.
Purpose:
Response to fluid challenge is often defined as an increase in cardiac index (CI) of more than 10-15%. However, in clinical practice CI values are often not available. We evaluated whether changes in mean arterial pressure (MAP) correlate with changes in CI after fluid challenge in patients with septic shock.
Methods:
This was an observational study in which we reviewed prospectively collected data from 51 septic shock patients in whom complete hemodynamic measurements had been obtained before and after a fluid challenge with 1,000 ml crystalloid (Hartman's solution) or 500 ml colloid (hydroxyethyl starch 6%). CI was measured using thermodilution. Patients were divided into two groups (responders and non-responders) according to their change in CI (responders: %CI >10%) after the fluid challenge. Statistical analysis was performed using a two-way analysis of variance test followed by a Student's t test with adjustment for multiple comparisons. Pearson's correlation and receiver operating characteristic curve analysis were also used.
Results:
Mean patient age was 67 ± 17 years and mean Sequential Organ Failure Assessment (SOFA) upon admittance to the intensive care unit was 10 ± 3. In the 25 responders, MAP increased from 69 ± 9 to 77 ± 9 mmHg, pulse pressure (PP) increased from 59 ± 15 to 67 ± 16, and CI increased from 2.8 ± 0.8 to 3.4 ± 0.9 L/min/m(2) (all p < 0.001). There were no significant correlations between the changes in MAP, PP, and CI.
Conclusions:
Changes in MAP do not reliably track changes in CI after fluid challenge in patients with septic shock and, consequently, should be interpreted carefully when evaluating the response to fluid challenge in such patients.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Blood Pressure Imbalances and Circulatory Shock
Blood Pressure: Hypertension and Hypotension
Normal blood pressure is 120/80 mm Hg. Elevated blood pressure is 120-129/under 80 mm Hg. Hypertension, warranting treatment at 130/80 mm Hg, is often asymptomatic and can lead to severe cardiovascular events, aneurysms, peripheral arterial disease, chronic renal disease, or cardiac...