Candidate Gene Testing in Clinical Cohort Studies with Multiplexed Genotyping and Mass Spectrometry
Published on: June 21, 2018
Microfluidic amplification as a tool for massive parallel sequencing of the familial hypercholesterolemia genes
Silke Hollants1, Egbert J W Redeker, Gert Matthijs
1Laboratory for Molecular Diagnosis, Center for Human Genetics, University of Leuven, Leuven, Belgium.
Background:
Familial hypercholesterolemia (FH) is an autosomal dominant disorder that affects cholesterol metabolism and is an important risk factor for heart disease. Three different genes were causally linked to this disorder: LDLR (low density lipoprotein receptor), APOB [apolipoprotein B (including Ag(x) antigen)], and PCSK9 (proprotein convertase subtilisin/kexin type 9). We evaluated a new amplicon preparation tool for resequencing these genes on next generation sequencing (NGS) platforms.
Methods:
For the 3 genes, 38 primer pairs were designed and loaded on the Fluidigm Access Array, a microfluidic array in which a PCR was performed. We amplified 144 DNA samples (73 positive controls and 71 patient samples) and performed 3 sequencing runs on a GS FLX Titanium system from Roche 454, using pyrosequencing. Data were analyzed with the SeqNext module of the Sequence Pilot software.
Result:
From the 38 amplicons, 37 were amplified successfully, without any further optimization. Sequencing resulted in a mean coverage of the individual amplicons of 71-fold, 74-fold, and 117-fold for the 3 runs, respectively. In the positive controls, all known mutations were identified. In 29% of the patient samples, a pathogenic point mutation or small deletion/insertion was found. Large rearrangements were not detectable with NGS, but were picked up by multiplex ligation-dependent probe amplification.
Conclusions:
Combining a microfluidic amplification system with massive parallel sequencing is an effective method for mutation scanning in FH patients, which can be implemented in diagnostics. For data analysis, we propose a minimum variant frequency threshold of 20% and a minimum coverage of 25-fold.