Comparison of two measuring instruments, B-pro and SphygmoCor system as reference, to evaluate central systolic blood
Luis Garcia-Ortiz1, José I Recio-Rodríguez, Joan J Canales-Reina
1La Alamedilla Health Centre, Research unit, Castilla y León Health Service-SACYL, Salamanca, Spain. Lgarciao@usal.es
Abstract:
A comparison is made of central aortic systolic pressure (CASP) and the radial augmentation index (rAIx) estimated with the B-Pro device and SphygmoCor (as reference) in 104 healthy Caucasians without drug treatment, together with an analysis of the relationship between CASP and rAIx, and arterial stiffness. Peripheral and central blood pressure, and the rAIx were measured with B-pro and SphygmoCor, with determination of the central augmentation index (CAIx), pulse wave velocity (PWV), carotid intima-media thickness (IMT) and the ankle-brachial index (ABI). rAIx as determined with B-Pro was greater than measured with SphygmoCor (5.85; 95%CI: 1.75-9.96), in the same way as CASP, estimated from the transfer function (1.47; 95%CI: 0.47-2.47 mm Hg) and with the second peak of the radial wave (4.46; 95%CI: 2.80-6.12 mm Hg). The Pearson correlation coefficient for CASP with B-Pro and SphygmoCor was r = 0.937 (P < 0.01), with an intraclass correlation of 0.972 (95%CI: 0.959-0.981). In the case of rAIx, the correlation coefficient was r = 0.436 (P < 0.01), with an intraclass correlation of 0.599 (95% CI: 0.409-0.728). The correlation of CASP (B-pro) with PWV was r = 0.558 (P < 0.01), with CAIx r = 0.253 (P < 0.01) and with carotid IMT r = 0.442 (P < 0.01). The correlation of rAIx (B-Pro) with age was r = 0.369 (r < 0.01), and with CAIx r = 0.463 (P < 0.001). Central arterial pressure estimated with B-Pro in healthy Caucasians without drug treatment offers adequate validity vs. the reference standard (SphygmoCor). However, in the estimation of rAIx, some differences with respect to the reference standard have been detected, probably related to measurement of the second peak of the radial wave.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: