Related Experiment Video
Updated: May 25, 2026

Methods for ECG Evaluation of Indicators of Cardiac Risk, and Susceptibility to Aconitine-induced Arrhythmias in Rats Following Status Epilepticus
Published on: April 5, 2011
The effect of different dialysate magnesium concentrations on QTc dispersion in hemodialysis patients
Farsad Afshinnia1, Hardik Doshi, Panduranga S Rao
1Division of Nephrology, Department of Internal Medicine, University of Michigan Health System, Ann Arbor, MI, USA.
Background:
Electrolyte changes during dialysis affect corrected QT (QTc) and QTc dispersion (QTcd), a surrogate marker of arrhythmogenicity. The impact of magnesium on QTcd is not clear.
Methods:
Twenty-two stable patients on maintenance hemodialysis were enrolled in this study. Each underwent two consecutive hemodialysis sessions at least 2 days apart, the first against normal magnesium dialysate (with magnesium at 1.8 mg/dL) followed by a low magnesium dialysate (with magnesium at 0.6 mg/dL). Pre- and post-dialysis weights, blood pressure, electrolytes, and 12-lead surface EKG were recorded. The QT interval and the QTcd were calculated before and after dialysis in both sessions.
Results:
Of 22 patients, 16 were female. The mean age ± SD was 53.7 ± 18.0 years. The mean change of QTcd (pre- vs. post-dialysis) was 9.5 ms (p = 0.120) and 9.3 ms (p = 0.145) in low and normal magnesium groups, respectively. Using univariate analysis, there was a statistically significant decrease in the mean blood pressure, weight, potassium, magnesium, and QTc interval post-dialysis (compared to pre-dialysis) in both groups (p ≤ 0.049). Post-dialysis concentrations of sodium and calcium were unchanged (compared to pre-dialysis) but bicarbonate increased with both dialysate groups (p < 0.001). The mean change of QTcd was not significant pre- versus post-dialysis by univariate analysis in either group. Multiple linear regression analysis adjusting for pertinent factors did not change the results in either of the two groups.
Conclusion:
Using a low magnesium dialysate bath in hemodynamically stable hemodialysis patients without preexisting advanced cardiac disease does not significantly impact QTcd.