Related Experiment Video
Updated: May 25, 2026

Combining Solid-state and Solution-based Techniques: Synthesis and Reactivity of Chalcogenidoplumbates(II or IV)
Published on: December 29, 2016
Application of 204mPb perturbed angular correlation of γ-rays spectroscopy in coordination chemistry
Johan Vibenholt1, Magnus Schau-Magnussen, Monika Stachura
1Department of Chemistry, University of Copenhagen, Universitetsparken 5, DK-2100 København Ø, Denmark.
Abstract:
(204m)Pb perturbed angular correlation of γ-rays (PAC) spectroscopy has been applied successfully for the first time to detect the nuclear quadrupole interaction in a lead(II) coordination compound in a molecular crystal [tetraphenylarsonium lead(II) isomaleonitriledithiolate ([AsPh(4)](4)[Pb(2)(i-mnt)(4)])]. The recorded parameters from a powder crystalline sample are ν(Q) = 0.178(1) GHz and η = 0.970(7). The electric field gradient (EFG) was determined at the PW91/QZ4P level including relativistic effects using the two-component zeroth-order regular approximation method for both the [Pb(i-mnt)(2)](2-) monomer and the [Pb(2)(i-mnt)(4)](4-) dimer. Only the EFG for the latter compares favorably with the experimental data, indicating that the picture of this complex as a prototypical hemidirected coordination geometry with a stereochemically active lone pair on lead(II) is inadequate. Advantages and limitations of (204m)Pb PAC spectroscopy as a novel technique to elucidate the electronic and molecular structures of lead-containing complexes and biomolecules are presented.
More Related Videos
05:51Isotopic Effect in Double Proton Transfer Process of Porphycene Investigated by Enhanced QM/MM Method
Published on: July 19, 2019
10:52Line Shape Analysis of Dynamic NMR Spectra for Characterizing Coordination Sphere Rearrangements at a Chiral Rhenium Polyhydride Complex
Published on: July 27, 2022
Related Concept Videos
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
π Electron Effects on Chemical Shift: Overview
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...