Related Experiment Video
Updated: May 25, 2026

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
Published on: August 5, 2021
Assessment of vertical root fractures using three imaging modalities: cone beam CT, intraoral digital radiography and
J Kambungton1, A Janhom, S Prapayasatok
1Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University, Thailand.
Objectives:
The aim of this study was to assess the accuracy of cone beam CT (CBCT) in detecting vertical root fractures and to compare the accuracy with images from an intraoral sensor and from conventional intraoral film.
Methods:
60 extracted, single-rooted human teeth were divided equally into two groups: a control group of 30 teeth and an induced fracture group of 30 teeth. All teeth were randomly placed into sockets in six dry mandibles. Each tooth was imaged by three modalities: CBCT, intraoral digital radiography and intraoral F-speed film. Three beam angulations (an orthogonal projection and additional projections with ± 20° horizontal shifts of the central ray) were used when radiographs were made using film and a digital sensor. Three oral and maxillofacial radiologists evaluated the presence of root fractures twice in each image modality using a five-point confidence rating scale. Areas under receiver operating characteristic curves (A(z)) were computed for each observer and modality and were tested for statistical differences using the Kruskal-Wallis test.
Results:
There was no statistical difference in the performance of the three modalities (mean of A(z) values: CBCT = 0.811, film = 0.797 and sensor = 0.775; p = 0.771).
Conclusions:
There was no significant difference between intraoral film, a high-resolution complementary metal oxide semiconductor digital imaging system and CBCT in detecting vertical root fractures in mandibular single-rooted teeth.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
X-ray Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...