Related Experiment Video
Updated: May 25, 2026

Novel and Innovative Hybrid Technique for Type A Aortic Dissection
Published on: March 28, 2025
[Single-stage procedure for multiple dissected aortic aneurysms with coagulopathy in an elderly patient]
Hiroki Satoh1, Kazuo Yamamoto, Satoshi Takahashi
1Department of Cardiovascular Surgery, Tachikawa Medical Center, Nagaoka, Japan.
Abstract:
An 86-year-old man was admitted for abdominal pain. Dissected descending thoracic aortic aneurysm and infrarenal abdominal aortic aneurysm were observed under computed tomographic (CT) scan. Hematologic studies revealed low platelet count and an increase in fibrin degradation products (FDP), and disseminated intravascular coagulation( DIC) associated with dissecting aortic aneurysm was highly suspected. Platelet transfusion was performed and gabexate mesilate was administered, however, no improvement of DIC could be obtained. An increase in aortic diameter was observed under CT scan and surgery was performed. The infrarenal aneurysm was replaced with a bifurcated prosthetic graft under open repair. Simultaneously, an endovascular stent-graft was delivered from the left limb of the abdominal graft and implanted into the descending thoracic aorta. The postoperative recovery was uneventful but platelet count did not improve in this case.