Echocardiographic Evaluation of Atrial Communications before Transcatheter Closure
Published on: February 8, 2022
Can computer tomography help predict feasibility of transseptal puncture after percutaneous closure of an interatrial
1Interventional Cardiology, HerzZentrum Hirslanden, Witellikerstrasse 36, 8008 Zürich, Switzerland. wagdi@herzzentrum.ch
Background:
Transseptal puncture (TSP) is the first step in pulmonary vein isolation and catheter ablation, as well as in left atrial appendage closure in atrial fibrillation. Although TSP has been reported to be successful in patients with device closure of interatrial septal communications, questions pertinent to its feasibility in patients with large devices still remain. We sought to determine whether a "safe zone" for TSP could be visualised by computer tomography (CT), especially if larger device sizes for interatrial septal communication closure (IASC-C) had been used.
Methods:
Retrospective observational study of 20 patients who underwent CT for de novo chest pain occurring after IASC-C or as a diagnostic test for suspected or proven coronary artery disease (CAD). Clinical follow-up was for 20.5 ± 17.6 (6-84) months. CT was done 18 ± 10 (2-28) weeks after IASC-C. Device size and dimensions of both atria in the long and short axes were measured, as was the minimal distance of the device edge to the inferior and inferoposterior atrial floor.
Results:
The calculated minimal distance from the device edge to the inferior aspect (at 6 o'clock) of the (right or left) atrial floor was 7.2 ± 6.5 (0-27) mm while that to the inferoposterior aspect (at 07:30 o'clock) was 5.3 ± 4.2 (0-15) mm. In both locations, a distance of >6 mm was documented in ten patients (50%) while in nine patients (45%) a space of <6 mm was shown in both locations. There was no correlation between atrial dimensions or device size and minimal device distance to either wall. Conclusion With the exception of cases with the smallest devices (18 and 20 mm), neither device size nor atrial dimensions allow us to predict the feasibility of TSP in patients with a clamshell-type interatrial septal device in place, so that CT may be of help in determining whether a safe puncture space does exist in these patients.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
07:39Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Mitral Stenosis II: Clinical features and Diagnostic Tests